Aller au contenu Aller à la navigation Aller au pied de page
Logo Akfix Logo X Chem Maroc - Distributeur officiel Akfix au Maroc

Pro tool · Estimate

Chemical anchor calculator Akfix C900

Estimate in seconds the number of chemical anchor cartridges needed based on drilling hole diameter, anchoring depth and number of fixings to install.

Site parameters

Millimeters

Standard: 12 Millimeters for M10 rod, 14 Millimeters for M12, 16 Millimeters for M16

Millimeters

E.g.: 8 (M8), 10 (M10), 12 (M12), 16 (M16), 20 (M20)

Millimeters

Min: 8 x rod diameter (e.g. 80 Millimeters for M10). Recommended: 10-12 x diameter.

units

Akfix C900 estimate

Volume per fixing

4.9 ml / fixing

Calculation: cylindrical hole volume - rod volume (annular gap)

Total volume needed

118 ml

with safety margin +20% (purge waste + nozzle fill)

Number of cartridges

1

cartridges of 410 ml

Estimate breakdown

  • Drilling: 14 Millimeters
  • Rod: 12 Millimeters
  • Anchoring depth: 120 Millimeters
  • Fixings: 20

Chemical anchor best practices

1

Drill at the right diameter

The hole diameter must be 2 to 4 Millimeters larger than the rod diameter to allow annular sealing. M10 -> 12 Millimeters hole. M12 -> 14 Millimeters hole.

2

Clean the hole

Brush with nylon brush + blow 3 alternating times to remove concrete dust. A dusty cavity divides pull-out resistance by 3.

3

Purge the cartridge

Before each new cartridge or after a pause, purge 15-20 cm of mix until the colour is uniform (correct resin + hardener mix).

4

Respect cure time

Do not load the anchor before complete cure: 45 min at 20 deg C, up to 24 h at 0 deg C. Exact values are on the technical datasheet depending on substrate temperature.